Duct Smoke Detector Installed

Location And Installation Of Detectors In Air Duct Systems Fire Alarms Certified

Location And Installation Of Detectors In Air Duct Systems Fire Alarms Certified

Smoke Detectors And Expected Conditions Fire Alarms Certified

Smoke Detectors And Expected Conditions Fire Alarms Certified

Source

Source

Duct Smoke Detector Installation Services Brampton

Duct Smoke Detector Installation Services Brampton

Where Should Duct Smoke Detectors Be Located Roger W Griffith P E

Where Should Duct Smoke Detectors Be Located Roger W Griffith P E

Fire Alarm Interface Of Smoke Dampers Ppt Download

Fire Alarm Interface Of Smoke Dampers Ppt Download

Fire Alarm Interface Of Smoke Dampers Ppt Download

With power source de energized and the smoke detector not installed wire all connections per engineering drawings.

Duct smoke detector installed.

Duct smoke sensors are made to detect early smoke or combustion particles present in the air travelling through hvac passways. The international mechanical code imc specifies that if the space is air conditioned and the a c unit is over 2 000 cfm a duct smoke detector is required to be installed in the return air duct. One sampling tube end cap 5. Refer to the applicable figures below depending on your duct housing model number.

One unit can accommodate multiple installation footprints to overcome mounting constraints. Both nfpa 90 and imc 606 2 1 state similar things that can be summarized and paraphrased as if the duct system is designed for more than 2000 cfm the system must have a duct smoke detector installed and if the duct system is designed for more than 15 000 cfm one in the return and supply is required. Sensor power board assembly and cover s 2. With all wiring in place install the detector head.

4 contents of the duct smoke detector kit 1. The duct smoke sensors are installed in the air duct system to detect any smoke in the duct. Nfpa 90a requires the first duct smoke detector to be installed on the supply side of air handler units of more than 2 000 cubic feet per minute cfm and requires one on the return side of units of more than 15 000 cfm and serving more than one story. Three 10 sheet metal screws for mounting 3.

Hvac duct smoke detection. Install return side detectors at a point before the return air stream is diluted by outside air. Innovairflex duct smoke detectors combine an impressive collection of innovations to greatly simplify hvac system monitoring. Energize the duct detector.

It must be the correct length for the width of the duct where it will be installed. One plastic exhaust tube note. Therefore they should complement the buildings fire detection system and not serve as the primary fire detection system. Install the duct smoke detector on a flat section of hvac duct between six and ten duct widths from any bends or obstructions.

Nor should it serve as an early warning detection system. Tool free plug in sampling tubes speed and simplify installation. Install supply side detectors at a point downstream from the supply fan and after the air filter.

Using A Manometer To Test Duct Smoke Detectors Fire Alarms Online

Using A Manometer To Test Duct Smoke Detectors Fire Alarms Online

Air Handler Smoke Detectors And The Nfpa Hvac Heating Cooling

Air Handler Smoke Detectors And The Nfpa Hvac Heating Cooling

Duct Smoke Detector Brampton Smoke Alarms Installation Testing Services Brampton Ontario

Duct Smoke Detector Brampton Smoke Alarms Installation Testing Services Brampton Ontario

System Sensor D4120 Tamper Troubles Fire Alarms Online

System Sensor D4120 Tamper Troubles Fire Alarms Online

Source : pinterest.com